HBO Triple Lock Medical Chamber

Category: Brand:
Article number: HYOT 2700-12-2-12-RD

A multi-place hyperbaric oxygen chamber designed for safe, comfortable and efficient clinical HBOT treatments.

In need of a user manual? Please download the request form.

Aantal
Add to Quote
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />

Questions?

If you have any questions let us know

Product description

Triple Lock Hyperbaric Oxygen Chamber

The Triple Lock hyperbaric oxygen chamber is a cylindrical multi-place HBOT system designed for professional medical environments. Its three-compartment configuration consists of an Entrance Lock, Main Chamber 1 and Main Chamber 2, with capacity for simultaneous treatment of up to 24 patients plus attendants.

The chamber combines clinical treatment capability with advanced monitoring, redundant control systems and a flexible interior configuration for routine and intensive hyperbaric operations.

Flexible Clinical Treatment

Rectangular doors provide access for wheelchairs and stretchers, while the modular interior allows operators to switch quickly between seating and stretcher configurations. Luxury fire-retardant seating includes adjustable backrests, foldable armrests and integrated leg and foot support.

The Built-In Breathing System supports air at 21% O₂, 100% oxygen and optional Heliox. Operators can manage simultaneous gas switching per chamber, while masks and hood tents can operate at the same time.

An overboard exhaust system directs exhaled gas outside the building. Safety regulators help prevent excessive negative pressure, while fully oxygen-compatible materials and rigid oxygen piping support safe operation.

Advanced Control and Monitoring

A central ergonomic control console with PLC and HMI touchscreen gives operators access to real-time pressure profiles and chamber parameter visualization. The system supports fully automatic, semi-automatic and fully manual operation.

Computer-controlled pressurization and depressurization operate alongside manual pressure control valves, independent pressure gauges for each compartment and emergency exhaust valves for rapid depressurization. A secondary pressure control system also supports full manual operation when required.

Continuous O₂ and CO₂ monitoring helps maintain controlled chamber conditions. Automatic flushing with adjustable rates supports atmosphere management, while the system automatically shuts off oxygen if O₂ levels exceed 23%. Visual and acoustic alarms provide additional warning during unsafe conditions.

The system also includes an operator presence safety check every three minutes, with automatic depressurization if the operator fails to respond.

Patient Comfort and Observation

The chamber environment is designed to support patient comfort throughout extended treatment sessions. Individual reading lights are fitted at each seat, while LED chamber lighting offers dimming and low heat emission.

Heating and cooling are controlled through heat exchangers in each main chamber, a chiller system and a hot water heating system. Controlled temperature fluctuation limits help maintain a stable internal environment, while silenced climate-control housings and low-noise gas inlet and exhaust systems reduce disturbance.

Large viewports improve visibility between patients and operators. A nine-camera observation system provides additional visual monitoring throughout the chamber.

Internal information panels display time, remaining session time, pressure, temperature and mask on/off status, giving occupants clear information during treatment.

Communication and System Integration

Two-way communication operates in all compartments through an integrated intercom, speakers and microphones. A fully independent battery-powered backup communication system provides additional redundancy.

The chamber also includes an entertainment system with USB and SD support. Medical-grade penetrators provide dedicated interfaces for gas, power and monitoring equipment.

Integrated Safety and Redundancy

The chamber incorporates a certified hyperbaric water fire suppression system with sprinklers and portable extinguishers inside the chamber. The fire system supports redundant activation from both inside the chamber and the control console.

During a fire event, the system automatically switches from oxygen to air. The fire safety system complies with EN 16081.

Primary low-pressure and secondary high-pressure air supply systems provide further operational redundancy. Automatic emergency switchover allows the backup air system to take over when required, while the available air reserves support extended emergency operation. Breathing air quality complies with EN 12021.

Data Logging and Traceability

The system supports full treatment session logging for pressure profiles, gas concentrations, temperature, humidity and session timing. Operators can review this information through graphical and numerical displays.

All compartments can be monitored simultaneously, giving the control team a complete overview of chamber conditions and treatment progress.

Compliance and Certification

The system is designed to comply with MDR 2017/745 for medical devices, PED 2014/68/EU for pressure equipment, EN 14931 for PVHO requirements, EN 16081 for fire safety and EN 12021 for breathing air quality.

Viewports comply with ASME-PVHO-1. The chamber carries CE marking for the EU and is supported by an ISO 13485 certified quality management system.

Specifications

Specification Value
Chamber type Cylindrical multi-place hyperbaric oxygen treatment (HBOT) chamber
Configuration Triple-lock
Compartments Entrance Lock (EL), Main Chamber 1 (MC1), Main Chamber 2 (MC2)
Treatment capacity Up to 24 patients + attendants simultaneously
Doors Rectangular, allowing access for wheelchairs and stretchers
Interior Modular, allowing quick change between seats and stretchers
Seating Luxury, fire-retardant
Seat backrests Adjustable
Seat armrests Foldable
Leg/foot support Included
Reading lights Individual per seat
Climate control Heating & cooling
Gas inlet/exhaust system Low-noise with silencers
Viewports Large
Breathing system Built-In Breathing System (BIBS)
BIBS air 21% O₂
BIBS oxygen 100% Oxygen
Heliox Optional
Gas switching Simultaneous gas switching per chamber
Exhaust system Overboard exhaust; exhaled gas expelled outside building
Safety regulators Prevent excessive negative pressure
Breathing interfaces Masks and hood tents usable simultaneously
Oxygen system materials Fully oxygen-compatible materials
Oxygen system piping Rigid piping
Gas inlet/exhaust valves Computer-controlled
Redundant gas control Manual
Chamber flushing Automatic with adjustable rates
Oxygen monitoring Continuous
CO₂ monitoring Continuous
Automatic oxygen shut-off If O₂ exceeds 23%
Alarms Visual and acoustic
Camera system 9 cameras total
Lighting LED with dimming and low heat emission
Penetrators Medical-grade for gas, power and monitoring
Internal information display Time & remaining session time, pressure, temperature, mask on/off status
Communication Two-way communication in all compartments
Communication equipment Intercom, speakers and microphones
Entertainment system USB / SD
Backup communication Fully independent, battery-powered
Control console Central ergonomic control console
Control system PLC + HMI touchscreen
Pressure display Real-time pressure profiles
Parameter display Chamber parameter visualization
Operation modes Fully automatic, semi-automatic, fully manual override
Operator presence check Every 3 minutes
Operator non-response action Automatic depressurization
Pressurization/depressurization Computer-controlled
Backup pressure control Manual pressure control valves
Pressure gauges Independent per compartment
Emergency exhaust Emergency exhaust valves for rapid depressurization
Secondary pressure control Full manual operation
Main chamber heat exchangers Heat exchangers in each main chamber
Cooling Chiller system
Heating Hot water system
Temperature control Controlled temperature fluctuation limits
Climate-control housings Silenced
Primary air supply Low-pressure air supply system
Secondary air supply High-pressure backup air system
Breathing air quality EN 12021
Emergency air switchover Automatic
Emergency air reserves Sufficient for extended emergency operation
Fire suppression Certified hyperbaric water fire suppression system
Fire-event gas switching Automatic switch from oxygen to air
Internal fire equipment Sprinklers and portable extinguishers
Fire safety standard EN 16081
Fire-system activation Redundant activation inside chamber + control console
Treatment logging Full treatment session logging
Logged pressure data Pressure profiles
Logged gas data Gas concentrations
Logged environmental data Temperature & humidity
Logged timing data Session timing
Data display Graphical and numerical
Monitoring Simultaneous monitoring of all compartments
Medical device compliance MDR 2017/745
Pressure equipment compliance PED 2014/68/EU
PVHO standard EN 14931
Fire safety compliance EN 16081
Breathing air compliance EN 12021
Viewport standard ASME-PVHO-1
CE marking EU
Quality management system ISO 13485 certified

 

Features

Key Functions & Features

Chamber Design & Capacity

  • Cylindrical multi-place hyperbaric oxygen treatment (HBOT) chamber
  • Triple-lock configuration:
    • Entrance Lock (EL)
    • Main Chamber 1 (MC1)
    • Main Chamber 2 (MC2)
  • Simultaneous treatment of up to 24 patients plus attendants
  • Rectangular doors allowing access for wheelchairs and stretchers
  • Modular interior allowing quick change between seats and stretchers

Patient Comfort & Usability

  • Luxury, fire-retardant seating with:
    • Adjustable backrests
    • Foldable armrests
    • Leg/foot support
  • Individual reading lights per seat
  • Climate-controlled environment with heating and cooling
  • Low-noise gas inlet/exhaust system with silencers
  • Large viewports for patient visibility and reassurance

Therapeutic Breathing System

  • Built-In Breathing System (BIBS) for:
    • Air (21% O₂)
    • 100% oxygen
    • Optional Heliox
  • Simultaneous gas switching per chamber
  • Overboard exhaust system, with exhaled gas expelled outside the building
  • Safety regulators preventing excessive negative pressure
  • Masks and hood tents can be used simultaneously
  • Fully oxygen-compatible materials and rigid piping for fire safety

Gas Control & Safety Systems

  • Computer-controlled gas inlet and exhaust valves
  • Manual redundant gas control system
  • Automatic chamber flushing with adjustable rates
  • Continuous monitoring of:
    • Oxygen concentration
    • CO₂ concentration
  • Automatic oxygen shut-off if O₂ exceeds 23%
  • Visual and acoustic alarms for unsafe conditions

Electrical & Monitoring Systems

  • Full camera observation system with 9 cameras
  • LED lighting with dimming and low heat emission
  • Medical-grade penetrators for gas, power and monitoring
  • Internal information panels showing:
    • Time and remaining session time
    • Pressure
    • Temperature
    • Mask on/off status

Communication & Entertainment

  • Two-way communication in all compartments
  • Intercom, speakers and microphones
  • Entertainment system with USB / SD
  • Fully independent battery-powered backup communication system

Control Console & Automation

  • Central ergonomic control console with:
    • PLC + HMI touchscreen
    • Real-time pressure profiles
    • Chamber parameter visualization
  • Three operation modes:
    • Fully automatic
    • Semi-automatic
    • Fully manual override
  • Operator presence safety check every 3 minutes
  • Automatic depressurization if the operator fails to respond

Pressure Control & Redundancy

  • Computer-controlled pressurization and depressurization
  • Manual pressure control valves as backup
  • Independent pressure gauges per compartment
  • Emergency exhaust valves for rapid depressurization
  • Secondary pressure control system for full manual operation

Climate Control

  • Heat exchangers in each main chamber
  • Chiller system for cooling
  • Hot water system for heating
  • Controlled temperature fluctuation limits
  • Silenced housings for patient comfort

Air Supply & Machinery

  • Primary low-pressure air supply system
  • Secondary high-pressure backup air system
  • Compliance with EN 12021 breathing air quality
  • Automatic switchover in emergency conditions
  • Sufficient air reserves for extended emergency operation

Fire Safety

  • Certified hyperbaric water fire suppression system
  • Automatic switch from oxygen to air during a fire event
  • Sprinklers and portable extinguishers inside the chamber
  • Certified to EN 16081
  • Redundant activation from:
    • Inside the chamber
    • Control console

Data Logging & Traceability

  • Full treatment session logging, including:
    • Pressure profiles
    • Gas concentrations
    • Temperature and humidity
    • Session timing
  • Graphical and numerical data display
  • Simultaneous monitoring of all compartments

Compliance & Certification

  • Designed to comply with:
    • MDR 2017/745 (Medical Devices)
    • PED 2014/68/EU
    • EN 14931 (PVHO)
    • EN 16081 (fire safety)
    • EN 12021 (breathing air)
    • ASME-PVHO-1 (viewports)
  • CE marking (EU)
  • ISO 13485 certified quality management system