Hyperbaric Fire Extinguisher 3L STSM2000

Category: Brand:
Article number: T.99.02630

Compact 3L foam fire extinguisher for Class A and B fires in hyperbaric environments, rated for depths up to 450 metres.

Aantal
Add to Quote
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />

Questions?

If you have any questions let us know

Product description

Improved product description

STSM 2000 Hyperbaric Foam Fire Extinguisher

The STSM 2000 is a compact hyperbaric foam fire extinguisher for use on Class A and B fires. As the smaller counterpart to the STSM 5000, it has a 3-litre cylinder with 2 litres of extinguishant while retaining a maximum working depth of 450 metres.

The extinguisher contains non-toxic aqueous foam and supports both intermittent and continuous discharge. Do not use the STSM 2000 on electrical fires over 24 volts.

The unit operates within a temperature range of 2°C to 50°C and has a maximum working pressure of 100 bar. It uses helium, nitrogen or bottom mix as propellant gas, provided the selected gas is compatible with the chamber atmosphere.

Pre-Dive Checks

Before a dive, check the extinguisher’s charge pressure. The required charge pressure ranges from 70 to 100 bar. For dives deeper than 200 metres, the charge pressure must be between 95 and 100 bar.

Check that the safety pin is correctly in place before use. The extinguisher should also be inspected for any signs of leakage, corrosion or mechanical damage as part of the pre-dive checks.

Operation

The STSM 2000 uses a simple operating procedure. Remove the safety pin and aim the nozzle at the base of the fire. Squeeze the trigger to activate the extinguisher.

The design allows both intermittent and continuous discharge, giving the operator control over the release of the aqueous foam extinguishant.

Maintenance and Recharging

The STSM 2000 can be recharged. Maintenance and recharging instructions are provided on the label on the reverse side of the cylinder.

With its 2-litre extinguishant volume and 3-litre total cylinder volume, the STSM 2000 provides a smaller-format option within the STSM hyperbaric foam extinguisher range. It combines its compact capacity with a maximum working depth of 450 metres and is specifically intended for Class A and B fires in hyperbaric conditions.

Specifications

Specification Detail
Product type Hyperbaric foam fire extinguisher
Model STSM 2000
Fire classes A and B
Electrical fire limitation Not to be used on electrical fires over 24 volts
Extinguishant type Non-toxic aqueous foam
Discharge Intermittent and continuous
Maximum working depth 450 metres
Operating temperature range 2°C to 50°C
Cylinder total volume 3 litres
Extinguishant volume 2 litres
Maximum working pressure 100 bar
Propellant gas Helium, nitrogen or bottom mix compatible with chamber atmosphere
Charge pressure 70 to 100 bar
Charge pressure for dives deeper than 200 metres 95 to 100 bar
Maintenance available
Recharging available

Features

  • Hyperbaric foam fire extinguisher
  • Suitable for Class A and B fires
  • Non-toxic aqueous foam
  • Rechargeable
  • Intermittent and continuous discharge
  • Maximum working depth of 450 metres
  • Operating temperature range of 2°C to 50°C
  • 2-litre extinguishant volume
  • 3-litre total cylinder volume
  • Safety pin
  • Trigger-operated discharge
  • Helium, nitrogen or bottom mix propellant gas compatible with chamber atmosphere