Contamination canister

Categories: , Brand:
Article number: 2.80.3963

The Hytech-Pommec contamination canister removes pollution from a breathing gas in an enclosed environment other than CO2 on moisture

Aantal
Add to Quote
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />
<br />
<b>Warning</b>:  Trying to access array offset on value of type null in <b>/home/hytechpommec/domains/hytech-pommec.nl/public_html/wp-content/themes/buro26/woocommerce/content-single-product.php</b> on line <b>66</b><br />

Questions?

If you have any questions let us know

Product description

Contamination Canister

The contamination canister removes human-generated contamination from enclosed environments caused by breathing, vomit, urine, feces and sweat.

Special Filter Blend

The canister contains a special blend of carbon molecular sieves and a catalyst. It removes urea, carbon monoxide, acetone, hydrogen chloride, hydrogen sulphite, carbonyl sulphite, hydrogen, methane, carbondisulphite and butyric acid.

The canister remains stored in an air tight container and starts working once opened and exposed to the environment.

Duration

Each canister lasts for at least 450 hours/person. Calculate the duration by dividing 450 by the number of occupants. For example, with 18 occupants, one canister lasts 25 hours. Three canisters are therefore required for 72 hours.

Following chemical components shall be eliminated:
• Urea (NH2) 2CO from urine
• Carbon monoxide (CO) from endogenous production
• Acetone (GH3 COCH3) metabolic and from organic waste
• Hydrogen chloride (HCL) from vomit
• Hydrogen sulphite (H2S) from feces/intestinal gas
• Carbonyl sulphite (OCS) from intestinal gas
• Hydrogen (H) from intestinal gas
• Methane (CH4) from intestinal gas
• Carbondisulphite (CS2) from intestinal gas
• Butyric acid (C3H1COOH) from intestinal gas

The contamination canister contains a special blend of carbon molecular sieves and a catalyst and is stored in an air tight container. Once the container is opened and the canister is exposed to the environment it starts to work. The canister will last for at least 450 hours/person.
Duration of a canister can be calculated as follows: Divide 450 by number of occupants = hours of duration. Example: a hyperbaric life boat is occupied by 18 persons duration of one canister shall last for 450:18 = 25 hours. So for 72 hours three canisters are needed (72:25=2.88).

Refill contamination canister: T.98.00552
O-ring scrubber-canister: H.70.00310

Specifications

Specification Detail
Product type Contamination canister
Filter media Carbon molecular sieves and catalyst
Storage Air tight container
Activation Starts working once exposed to the environment
Capacity At least 450 hours/person
Duration calculation 450 ÷ number of occupants = hours of duration
Example duration 18 occupants = 25 hours per canister
Example requirement 3 canisters for 72 hours with 18 occupants
Refill contamination canister T.98.00552
O-ring scrubber-canister H.70.00310

Features

  • Removes human-generated contamination in enclosed environments
  • Targets contamination from breathing, vomit, urine, feces and sweat
  • Special blend of carbon molecular sieves and catalyst
  • Starts working once exposed to the environment
  • Minimum capacity of 450 hours/person
  • Duration calculated as 450 ÷ number of occupants
  • Removes urea, carbon monoxide, acetone, hydrogen chloride, hydrogen sulphite, carbonyl sulphite, hydrogen, methane, carbondisulphite and butyric acid